SAE ARP598 PDF

Original price was: $99.00.Current price is: $56.43.

PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD

PDF Format Searchable Printable Bookmarks
Guaranteed Safe Checkout

Description

This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (±33% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.

History

ARP598D 2016-06-09 Latest Canceled
ARP598C 2003-01-11 Historical Revised
ARP598B 1991-11-01 Historical Reaffirmed
ARP598A 1969-08-01 Historical Revised
ARP598 1991-11-01 Historical Reaffirmed
ISSUING COMMITTEE

A-6C1 Fluids and Contamination Control Committee

DATE

1991-11-01

DOI

https://doi.org/10.4271/ARP598

ISCURRENT
PAGE

11

PUBLISHER

SAE International

REVISED

ISSUED

Reviews