SAE ARP598A PDF
Original price was: $86.00.$49.02Current price is: $49.02.
THE DETERMINATION OF PARTICULATE CONTAMINATION IN LIQUIDS BY THE PARTICLE COUNT METHOD
Description
This method describes a procedure for the sizing and counting of particulate contamination in liquid samples by membrane filtration. The procedure will allow measurement of particulate contamination five microns or greater in size with a maximum variation of ±20% in results over an average of two runs. This procedure can be used for all samples where the membrane filter is compatible with the sample liquid and rinse liquid.
History
| ARP598D | 2016-06-09 | Latest | Canceled |
| ARP598C | 2003-01-11 | Historical | Revised |
| ARP598B | 1991-11-01 | Historical | Reaffirmed |
| ARP598A | 1969-08-01 | Historical | Revised |
| ARP598 | 1991-11-01 | Historical | Reaffirmed |
| ISSUING COMMITTEE | A-6C1 Fluids and Contamination Control Committee |
|---|---|
| DATE | 1969-08-01 |
| DOI | |
| ISCURRENT | |
| PAGE | 8 |
| PUBLISHER | SAE International |
| REVISED | REVISED |
Please select a variation to view its pdf.






Reviews